Part Number Hot Search : 
C1005JB B2010 AD996112 5558GS7F AM53C96 COMPO MPX4200A IDT74CB
Product Description
Full Text Search
 

To Download SGT967360E Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  page 1 / 4 f/uk s/tri/SGT967360E/c/30/07/2014 SGT967360E sortie / output : 3x75a/24-600vac entre / input : 10-30vdc caractristiques sujettes modifications sans pravis. all technical characteristics are subject to change without previous notice. celduc ? ? ? ? r e l a i s proud to serve you caractristiques de commande ( 20c) / control characteristics (at 20c) paramtre / parameter tension de commande / control voltage symbol uc min 10 nom 24 max 30 unit vdc courant de commande / control current (@ uc ) tension de relachement/ release voltage rsistance interne / i nput internal resistor (fig.1) tension inverse / reverse voltage ic uc off 10 4 rc urv 35 46 550 30 madc vdc vdc caractristiques gnrales / general characteristics isolement entre-sortie/ input-output isolation @500m isolement sortie-semelle/ output-case isolation @500m tension assigne isolement/ rated impulse voltage ui ui uimp poids/ weight temprature de stockage / storage temperature temprature de fonctionnement/ operating temperature rsistance d'isolement / insulation resistance @500vdc ri 4000 3300 4000 vrms vrms v 370 -40 / +100 -40 / +100 1000 g c c m humidit relative / relative humidity altitude maximale / max. altitude hr 40 to 85 2000 % m 0 5 10 15 20 25 30 uc(v) 0 10 20 30 40 50 ic(ma) fig. 1 :caractristique d'entre / control characteristic circuit quivalent/ equivalent circuit : r s t resistive inductive lo r s t application typique / typical application : relais statique triphas three phase solid state relay entraxe 47,5mm /47.5mm mounting ? relais statique synchrone triphas adapt aux charges rsistives. three phase zero-cross solid state relay designed for resistive loads. ? sorties thyristors hautes performances technologie tms 2 (*) permettant une longue dure de vie et de forts courants de surcharge new h igh e fficiency back to back thyristors on output with tms 2 technology(*) for a long lifetime expectancy and high surge currents ? led de visualisation sur l'entre de couleur verte. green led visualization on the input. ? construit en conformit aux normes en60947-4-3 (cei60947-4-3), cei62314 et ul-cul designed in conformity with en60947-4-3 (iec60947-4-3), iec62314 and ul-cul
page 2 / 4 f/uk caractristiques thermiques / thermal curves : s/tri/SGT967360E/c/30/07/2014 caractristiques de sortie / output characteristics (at 25c) paramtre / parameter plage de tension utilisation / operating voltage range conditions symbol ue min 24 typ. 400 max 600 unit v rms tension de crte / peak voltage niveau de synchronisme / zero cross level tension minimum amor?age / latching voltage courant nominal / nominal current (ac-51) up usync ie nom ac-51 / lc-a ua ie 1200 10 75 35 v v 90 v a rms courant surcharge / non repetitive overload current chute directe l'tat passant / on state voltage drop rsistance dynamique / on state dynamic resistance puissance dissipe (max) / output power dissipation (max value) tp=10ms (fig. 3) @ 25c itsm vt rt pd rsistance thermique jonction/semelle thermal resistance between junction to case courant de fuite l'tat bloqu / off state leakage current courant minimum de charge / minimum load current temps de fermeture / turn on time @ue typ, 50hz rthj/c ilk @ue typ, 50hz iemin ton max 1100 1200 3x(0,9x1xie + 0,0045 x ie 2 ) 1 a v 4,5 m w 0,27 5 0,4 1 k/w ma 10 ma ms temps d'ouverture / turn off time frquence utilisation / operating frequency range dv/dt l'tat bloqu / off state dv/dt di/dt max / maximum di/dt non repetitive @ue typ, 50hz f mains toff max f dv/dt di/dt i 2 t (limite de fusion) / i 2 t (melting limit ) immunit conduite / conducted immunity level immunit conduite / conducted immunity level protection court-circuit / short circuit protection <10ms iec/en61000-4-4 (bursts) i 2 t iec/en61000-4-5 (surge) type 2 example 0,1 50-60 500 10 800 ms hz 50 v/s a/s 6000 7200 2kv criterion b 2kv criterion a with external vdr fuse mersen grc80a a 2 s r e l a i s 5 rue ampre b.p. 30004 42290 sorbiers - france e-mail : celduc-relais@celduc.com fax +33 (0) 4 77 53 85 51 service commercial france tl. : +33 (0) 4 77 53 90 20 sales dept.for europe tel. : +33 (0) 4 77 53 90 21 sales dept. asia : tl. +33 (0) 4 77 53 90 19 www.celduc.com celduc ? ? ? ? 0 20 40 60 80 courant de charge / rms load current (a) 0 20 40 60 80 100 120 140 160 180 200 220 240 260 puissance dissipe / power dissipation (w) 0 10 20 30 40 50 60 70 80 90 100 temprature ambiante / ambient temperature (c) 0 20 40 60 80 100 120 140 160 180 200 220 240 260 6k/w 2,1k/w 1,5k/w full on state 50% on state 0,95k/ w 0,75k/ w 0,55k/ w 0,3k/w
page 3 / 4 f/uk s/tri/SGT967360E/c/30/07/2014 fig 3 : courants de surcharges / overload currents ? > warning ! semiconductor relays don't provide any galvanic insulation between the load and the mains. always use in conjunction with an adapted circuit breaker with isolation feature or a similar device in order to ensure a reliable insulation in the ev ent of wrong function and when the relay must be insulated from the mains (maintenance ; if not used for a long duration ...). 1 -itsm non rptitif sans tension rapplique est donn pour la dtermination des protections. 1 - non repetitive itsm is given without voltage reapplied . this curve is used to define the protection (fuses). 2 -itsm rptitif est donn pour des surcharges de courant (tj initiale=70c). attention : la rptition de ces surcharges de courant diminue la dure de vie du relais. 2 - repetitive itsm is given for inrush current with initial tj = 70c. in normal operation , this curve musn't be exceeded. be careful, the repetition of the surge current decreases the life expectancy of the ssr. ? > attention ! les relais semi-conducteurs ne procurent pas d'isolation galvanique entre le rseau et la charge. ils doivent tre utilis s associs un disjoncteur avec proprit de sectionnement ou similaire, afin d'assurer un sectionnement fiable en amont de la l igne dans l'hypothse d'une dfaillance et pour tous les cas o le relais doit tre isol du rseau (maintenance ; non utilisation sur un e longue dure...). avec capot 1k199000 with transparent cover 1k199000 dimensions r e l a i s 5 rue ampre b.p. 30004 42290 sorbiers - france e-mail : celduc-relais@celduc.com fax +33 (0) 4 77 53 85 51 service commercial france tl. : +33 (0) 4 77 53 90 20 sales dept.for europe tel. : +33 (0) 4 77 53 90 21 sales dept. asia : tl. +33 (0) 4 77 53 90 19 www.celduc.com celduc ? ? ? ? 1/l1 3/l2 5/l3 4/t2 6/t3 a1+ 2/t 1 a2- 0,01 0,1 1 10 t (s) 0 500 1000 itsm (apeak) surge current itsm (a peak) = f(t) for models 75a he
page 4 /4 f/uk s/tri/SGT967360E/c/30/07/2014 sgt raccordement d'entre / control wiring 1 nombre de fils / number of wires 2 modle de tournevis / screwdriver type couple de serrage recommand recommended torque fil rigide (sans embout) solid (no ferrule) 0,75 ... 2,5 mm 2 awg18....awg14 fil multibrins (avec embout) fine stranded (with ferrule) fil rigide (sans embout) solid (no ferrule) 0,75 ... 2,5 mm 2 awg18....awg14 0,75 ... 2,5 mm 2 awg18....awg14 fil multibrins (avec embout) fine stranded (with ferrule) 0,75 ... 2,5 mm 2 awg18....awg14 pozidriv 2 m4 n.m 1,2 raccordement de puissance / power wiring 1 nombre de fils / number of wires 2 modle de tournevis / screwdriver type couple de serrage recommand recommended torque fil rigide (sans embout) solid (no ferrule) 1,5 ... 10 mm 2 awg16....awg8 fil multibrins (avec embout) fine stranded (with ferrule) fil rigide (sans embout) solid (no ferrule) 1,5 ... 6 mm 2 awg16....awg10 1,5 ... 10 mm 2 awg16....awg8 fil multibrins (avec embout) fine stranded (with ferrule) 1,5 ... 6 mm 2 awg16....awg10 pozidriv 2 m5 n.m 2 puissance avec cosses / power with ring terminals. w max = 12,6mm 16 mm 2 (awg6) 25 mm 2 (awg4) 35mm 2 (awg2 /awg3) 50mm 2 (awg0 /awg1) connexions de puissance m5 m5 power connections connexions de commande m4 m4 control connections nouvelles bornes avec rondelles freins new terminals with blocking washers connexions / terminals r e l a i s 5 rue ampre b.p. 30004 42290 sorbiers - france e-mail : celduc-relais@celduc.com fax +33 (0) 4 77 53 85 51 service commercial france tl. : +33 (0) 4 77 53 90 20 sales dept.for europe tel. : +33 (0) 4 77 53 90 21 sales dept. asia : tl. +33 (0) 4 77 53 90 19 www.celduc.com celduc ? ? ? ?


▲Up To Search▲   

 
Price & Availability of SGT967360E

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X